ABB PC D231 B PEC80-CCI UNITROL 6000 X-power PCD231B
ABB PC D231 B, designated PCD231B with part number 3BHE025541R0101 and named PEC80‑CCI, is a dedicated firing and communication interface board built for the UNITROL 6000 X‑power high‑current static excitation system based on AC 800PEC. It generates isolated thyristor firing pulses and samples three‑phase synchronizing voltage for excitation regulation. It acquires binary status of power bridges, fuses, cooling fans and field breakers, and outputs trip, block and alarm signals. Real‑time data is transmitted synchronously to PPD controllers over the CEX bus, while PROFIBUS‑DP and Modbus RTU links provide connection to plant DCS. Continuous diagnostics monitor pulse integrity, synchronization quality and hardware health, and store timestamped fault records for post‑trip analysis. This board is exclusive for UNITROL 6000 X‑power and is not interchangeable with general combined I/O boards such as D232 A and D235 A.
ABB PC D231 B PEC80-CCI UNITROL 6000 X-power PCD231B
| Parameter | Specification |
|---|---|
| Product Type | PEC80‑CCI Excitation Control & Communication Interface Board, PC D231 B |
| Compatible System | ABB AC 800PEC ControlIT, UNITROL 6000 X‑power high‑power static excitation system |
| Core Function | Thyristor firing pulse generation, synchronous voltage sampling, excitation closed‑loop front‑end interface; collect power bridge, fuse, fan and breaker status; output excitation blocking, trip and alarm commands; exchange real‑time excitation data with PPD processors via CEX bus; handle DCS and field communication for large generator excitation control |
| Signal Type | Three‑phase synchronizing AC inputs, isolated firing pulse outputs, precision analog measurement channels, 24 V DC isolated digital I/O, PROFIBUS‑DP, RS‑485 Modbus RTU, CEX high‑speed internal bus |
| Galvanic Isolation | Reinforced isolation for pulse, measurement and field communication channels, dielectric strength ≥ 2500 V AC, strong anti‑EMI performance for high‑power excitation cabinets |
| Power Supply | Redundant 24 V DC supplied by CompactPCI backplane |
| Power Consumption | Max 18 W |
| Diagnosis | Power‑on self‑test, synchronization angle plausibility check, pulse channel supervision, fuse and fan monitoring, supply rail supervision, overtemperature detection, timestamped fault log and disturbance recorder support |
| Indicator | RUN, FAULT, SYNC, PULSE and individual channel status LED indicators on front panel |
| Communication | Proprietary CEX internal bus, PROFIBUS‑DP, Modbus RTU |
| Hot Swap | Non hot‑swappable; de‑energize excitation power bridge, rack auxiliary supply and all field wiring before replacement |
| Operating Temperature | -10 ℃ ~ +70 ℃ |
| Storage Temperature | -40 ℃ ~ +85 ℃ |
| Humidity | 5% ~ 95% non‑condensing |
| Protection Class | IP00, installed inside sealed UNITROL 6000 X‑power excitation control rack |
| Certifications | CE, UL, IEC 61000, IEC 61131‑2 |
| Mounting | 6U CompactPCI slide‑in rack module for AC 800PEC rack |
| Application | Large hydro, thermal and gas turbine generator static excitation, UNITROL 6000 X‑power high current excitation cabinet |
| Remarks | PC D231 B, also known as PCD231B, PEC80‑CCI; official part number 3BHE025541R0101; dedicated front‑end firing and communication board for UNITROL 6000 X‑power; designed for high‑current thyristor excitation bridges; cannot be interchanged with D232 A / D235 A; matched with PPD103 / PPD113 / PPD512 controllers; fully function tested before shipment |

- D235 A