ALSTOM NRD108028 | 8RDB43655 | SA43655.E | Safety Control Card

Original price was: $3,800.00.Current price is: $1,580.00.

Brand: Alstom
Model: NRD108028 / 8RDB43655 / SA43655.E
Warranty Period: 365 days
Lead Time: In stock, 1 week
Payment Terms: 50% prepayment, full payment before shipment for in‑stock goods
Courier: FedEx, UPS, DHL
HS Code: 853890
Dimension: 160 × 100 × 20 mm
Net Weight: 0.25 kg
Gross Weight: 0.45 kg

Category: Brand:
Need This Part? Contact Us Get a quick quote and product availability.
Chat on WhatsApp
Scan to contact Massive PLC on WhatsApp Scan to chat

Description

ALSTOM NRD108028 | 8RDB43655 | SA43655.E | Safety Control Card

Alstom NRD108028 (assembly code 8RDB43655, drawing reference SA43655.E) is an eight‑channel relay output Eurocard for ALSPA P320 and TGP turbine control racks. It receives digital logic commands over the proprietary backplane bus and switches isolated SPDT relay contacts for critical interlocks, trip functions and alarm outputs. Onboard diagnostics monitor relay drive and contact feedback to detect hardware anomalies, and fault events are stored with timestamps. Designed for continuous operation in power plant and petrochemical control cabinets, this obsolete module remains an essential stocking spare for maintaining legacy Alstom turbine and distributed control systems.

ALSTOM NRD108028 | 8RDB43655 | SA43655.E | Safety Control Card

Parameter Specification
Product Type 8‑Channel Isolated Relay Output Module
Compatible System Alstom ALSPA P320, TGP turbine control and legacy power plant DCS rack
Core Function Receive logic commands from rack controller, drive isolated relay contacts for interlock, trip, alarm and status signalling; each channel supports independent contact supervision for protection and ESD loops
Signal Type 8 relay output channels, SPDT contact; contact rating: 250 VAC / 30 VDC, 5 A resistive; dedicated proprietary backplane bus
Galvanic Isolation Galvanic isolation between relay field side and rack logic backplane, dielectric strength ≥ 1500 V AC
Power Supply 24 V DC supplied by rack backplane
Power Consumption Max 5 W
Diagnosis Power‑on self‑test, relay drive supervision, contact feedback monitoring, watchdog, over‑temperature detection, fault timestamp logging
Indicator RUN, FAULT and individual channel status LED indicators on front panel
Communication Alstom proprietary rack backplane bus
Hot Swap Non hot‑swappable; rack auxiliary supply and field trip circuits must be locked out before replacement
Operating Temperature -25 ℃ ~ +70 ℃
Storage Temperature -40 ℃ ~ +85 ℃
Humidity 5% ~ 95% non‑condensing
Protection Class IP00, installed inside sealed control cabinet
Certifications CE, UL, IEC 61131‑2, IEC 61000‑6‑2 / IEC 61000‑6‑4 EMC compliant
Mounting 3U Eurocard slide‑in rack PCB
Application Thermal power turbine protection, boiler interlock, ESD and alarm annunciation, petrochemical process control
Remarks NRD108028: base part number; 8RDB43655: full assembly revision code; SA43655.E: schematic drawing reference; discontinued legacy spare, fully function tested before shipment