Description
Bently 9200-06-05-05-00 Velocity sensing transducer 920006050500
Bently Nevada 9200‑06‑05‑05‑00 is a passive moving‑coil seismoprobe for absolute casing vibration measurement. It produces analog voltage proportional to vibration velocity without external power supply. This ordering variant features 10 Hz low cut‑off frequency, top integral cable and M10 mounting stud, supporting wide mounting angular tolerance. Moving‑coil design provides good immunity against sharp impulse shock compared with accelerometers. It can be connected to Bently Nevada 3500 vibration monitor modules for permanent protection or paired with portable vibration collectors for periodic route surveys. Transverse sensitivity is strictly controlled, and the unit is qualified for heavy industrial environments. Replacement requires compatible monitor configuration and matched interconnect cable.
Bently 9200-06-05-05-00 Velocity sensing transducer 920006050500
| Parameter | Specification |
|---|---|
| Product Type | Two‑Wire Seismoprobe Velocity Transducer |
| Compatible System | Bently Nevada / Baker Hughes 3500, 1900, 1701 Machinery Monitoring Systems |
| Core Function | Absolute bearing housing and casing vibration measurement; moving‑coil passive sensor, generates voltage proportional to vibration velocity; applied for continuous online machinery protection and route vibration inspection |
| Signal Type | Self‑powered two‑wire voltage output, sensitivity 20 mV/mm/s (500 mV/in/s), tolerance ±5%; measurable velocity range 0.254–127 mm/s; frequency response 10 Hz to 1000 Hz |
| Galvanic Isolation | Internal coil isolated from metal housing; satisfies API 670 and industrial EMC requirements |
| Power Supply | Self‑powered, no external excitation required |
| Power Consumption | 0 W |
| Diagnosis | Diagnostics implemented by monitor module for cable break, short circuit and abnormal signal; passive sensor without built‑in diagnostic circuit |
| Indicator | No onboard LED indicators |
| Communication | Analog voltage signal output, wired to vibration monitor channel |
| Hot Swap | Not applicable, field mounted transducer |
| Operating Temperature | -29 ℃ ~ +121 ℃ |
| Storage Temperature | -40 ℃ ~ +130 ℃ |
| Humidity | 5% ~ 95%, non‑condensing |
| Protection Class | IP64 |
| Certifications | CSA certified |
| Mounting | 0 ±100° mounting orientation, M10 × 1 threaded stud base, top integral cable |
| Application | Steam turbine, gas turbine, centrifugal compressor, fan, gearbox and pump; casing absolute vibration protection for power, petrochemical and metallurgical plants |
| Remarks | 9200‑06‑05‑05‑00; minimum cutoff frequency 10 Hz (600 CPM); transverse sensitivity ≤10% of axial sensitivity; withstands 50 g peak transverse shock; still active production, commonly stocked spare; requires matching monitor input channel and extension cable |