Bently Nevada 9200‑09‑01‑02‑01 is a passive moving‑coil velocity transducer for absolute vibration measurement of bearing housings and machine casings. It generates a voltage signal proportional to vibration velocity without external power supply. This ordering variant features 15 Hz low cut‑off frequency, top connector without integral cable, 1/4‑28 UNF stud base and CSA certification. Compared with integrated accelerometers, moving‑coil seismoprobes are less sensitive to impulsive shock excitation. It is commonly wired to Bently Nevada 3500 velocity monitor channels for continuous machinery protection or used with portable vibration collectors. Transverse sensitivity is controlled below 10%, and the unit is qualified for heavy industrial environments. Replacement requires compatible monitor configuration and matched extension cable.
Bently 9200-09-01-02-01 Velocity transducer 920009010201
| Parameter | Specification |
|---|---|
| Product Type | Two‑Wire Seismoprobe Velocity Transducer |
| Compatible System | Bently Nevada / Baker Hughes 3500, 1900, 1701 Machinery Monitoring Systems |
| Core Function | Absolute casing / bearing housing vibration measurement; moving‑coil principle, self‑powered, outputs voltage proportional to vibration velocity; used for continuous online protection and periodic route inspection of rotating machinery |
| Signal Type | Two‑wire self‑generated voltage signal, sensitivity 20 mV/mm/s (500 mV/in/s), ±5%; peak velocity range 25 mm/s; max measurable displacement 2.54 mm peak |
| Galvanic Isolation | Internal coil isolated from housing; compliant with API 670 and industrial EMC requirements |
| Power Supply | Self‑powered, no external supply required |
| Power Consumption | 0 W |
| Diagnosis | External monitor module performs cable break, short and signal amplitude diagnostics; sensor itself passive |
| Indicator | No on‑board indicators |
| Communication | Analog voltage output, wired to monitor input channel |
| Hot Swap | Not applicable; field mounted sensor |
| Operating Temperature | -29 ℃ ~ +121 ℃ |
| Storage Temperature | -40 ℃ ~ +130 ℃ |
| Humidity | 5% ~ 95%, non‑condensing |
| Protection Class | IP64 |
| Certifications | CSA certified |
| Mounting | 1/4‑28 UNF threaded stud base, top connector, mounting orientation 0° ±180° |
| Application | Steam turbine, gas turbine, centrifugal compressor, fan, gearbox, pump; casing absolute vibration protection in power, petrochemical and mining |
| Remarks | 9200‑09‑01‑02‑01; minimum frequency response 15 Hz (900 CPM); transverse sensitivity ≤10% of axial sensitivity; withstands 50 g peak transverse mechanical shock; original production active, widely stocked spare; matching extension cable and velocity monitor input required |