Description
DEIF PCM42|PCM43|PCM44|IOM 4∙2|SCM 4∙1
This group consists of the core rack modules for DEIF Delomatic 400 and the discontinued AWC 400 controller family. PCM43 serves as the primary master CPU and rack power source, PCM42 is the redundant standby controller, and PCM44 handles expansion racks for large I/O layouts. IOM 4∙2 provides flexible isolated analogue and digital I/O for engine, valve and safety chain signals. SCM 4∙1 is the dedicated high‑speed electrical measurement and protection board for generator and grid parameters, supporting synchronisation and fast electrical trip protection. The whole set is widely used for gas engines, hydro turbines, offshore marine power plants and older wind turbine control systems.
DEIF PCM42|PCM43|PCM44|IOM 4∙2|SCM 4∙1
| Parameter | Specification |
|---|---|
| Product Type | Rack modular control suite: PCM42, PCM43, PCM44, IOM 4∙2, SCM 4∙1 |
| Compatible System | DEIF Delomatic 400, DM‑4 Gas, DM‑4 Marine, AWC 400 wind & hydro controller rack |
| PCM42 | Redundant standby power & control CPU, watchdog supervisor, hot standby master backup, 3 × CAN, RS485, ARCNET, Ethernet |
| PCM43 | Main master power & control CPU; supplies rack backplane power, runs main application logic, manages bus communication, IEC 61131‑3 programmable |
| PCM44 | Expansion chassis controller; links to main PCM43 via ARCNET, manages remote / secondary rack distributed I/O and fieldbus |
| IOM 4∙2 | Multifunction isolated I/O module; configurable digital input, digital relay output, analog 4–20 mA / 0–10 V, frequency input, safety chain & emergency stop handling |
| SCM 4∙1 | Precision AC measurement & fast protection module; class 0.5, direct up to 690 V, 1 A / 5 A CT input, generator / grid protection, synchro‑check, trip relay output |
| Rated Auxiliary Supply | 18–36 V DC, nominal 24 V DC |
| Communication | CAN 2.0, ARCNET, RS‑485, 10/100 Ethernet, backplane high‑speed internal bus |
| Memory | PCM series: 64 MB SDRAM, 16 MB Flash, NOVRAM for parameter retention |
| Measurement Accuracy | SCM 4∙1: Class 0.5 per IEC 60688; IOM 4∙2 analog: Class 1 |
| Diagnosis | Hardware watchdog, power supervision, wire break supervision, over‑range detection, built‑in self‑test, trip circuit monitoring |
| Indicator | LED for power, run, fault, bus activity, relay status |
| Hot Swap | Hot‑swappable within Delomatic 400 rack |
| Operating Temperature | -40 ℃ ~ +70 ℃ |
| Storage Temperature | -40 ℃ ~ +85 ℃ |
| Humidity | 5% ~ 95% non‑condensing |
| Protection Class | IP20 for rack mounted modules |
| Certifications | CE, EMC, DNV marine approval, wind turbine compliant |
| Mounting | Plug‑in eurocard, 8 TE width, standard Delomatic 400 subrack |
| Application | Gas engine genset, CHP, hydro turbine control, marine power management, wind turbine control, generator synchronisation & protection |
| Remarks | End‑of‑life legacy modular suite for Delomatic 400 / AWC 400; each module fully flashed, calibrated, bus & function tested before shipment |

- DEIF PCM42