TRICONEX 2401 DO2401 Digital Output Baseplate 24VDC | Pre-owned Tested
TRICONEX DO2401 (2401) is a triple modular redundancy high-current digital output baseplate designed for Trident safety instrumented systems. It provides 16 supervised 24VDC digital output channels, each channel supports up to 2A continuous current to drive heavy-load solenoid valves, safety relays and ESD shutdown actuators. It adopts TMR fault tolerant voting architecture, single channel failure will not result in dangerous output. Built-in circuit monitoring detects wiring open circuit, short circuit and overcurrent fault conditions and uploads fault events to the safety controller. The PCB is conformal coated for anti-corrosion and anti-moisture, suitable for hazardous industrial environments of petrochemical, oil & gas and power plant. It is a core spare component for Trident SIS platform, replacement requires strictly matched firmware and system configuration.
TRICONEX 2401 DO2401 Digital Output Baseplate 24VDC | Pre-owned Tested
| Parameter | Specification |
|---|---|
| Product Type | Digital Output Baseplate Module |
| Compatible System | TRICONEX Trident SIS Safety Instrumented System, TMR Safety Control Platform |
| Core Function | 16-channel 24VDC high-current digital output, TMR 2oo3 voting control, ESD emergency shutdown solenoid & safety relay drive, field circuit supervision, fault output latching, fire & gas protection control |
| Signal Type | 16 isolated digital output channels, 24VDC sink/source configurable, max 2A per channel, TriBus backplane interface |
| Galvanic Isolation | Channel-to-backplane reinforced isolation, EMC & surge protection for oil, gas and chemical hazardous zone |
| Power Supply | 24 V DC, 18–32 V DC wide input |
| Power Consumption | Max 11 W |
| Diagnosis | Power-on self-test, watchdog supervision, open/short circuit field wiring detection, overcurrent protection, channel discrepancy voting fault detection, fault logging & snapshot storage |
| Indicator | Onboard LED for power, pass, active, fault and field alarm |
| Communication | TriBus internal high-speed backplane bus, compatible with TriStation configuration software |
| Hot Swap | Hot swappable in matched Trident rack under redundant configuration |
| Operating Temperature | -20 ℃ ~ +60 ℃ |
| Storage Temperature | -40 ℃ ~ +85 ℃ |
| Humidity | 5% – 95%, non-condensing |
| Protection Class | IP20 when installed inside cabinet |
| Certifications | CE certified, IEC 61508 SIL3 certified |
| Mounting | Plug-in eurocard baseplate for TRICONEX Trident rack |
| Remarks | Model: 2401 / TRICONEX DO2401; TMR high-current digital output baseplate for SIS; conformal coated PCB; firmware version must match Trident system; critical spare for ESD solenoid and safety shutdown load control |