Description
Triconex 3006 MP3006 EMP II Main Processor 2MB SRAM
Triconex MP3006 EMP II is the core TMR main processor module for Tricon safety instrumented system. It adopts patented triple modular redundancy architecture, three independent CPU channels run safety logic synchronously and perform voting to realize high fault tolerance. Equipped with 2MB SRAM for safety program and process data storage, built-in TriBus high-speed backplane bus and multiple isolated serial interfaces to connect I/O modules and host communication. It supports emergency shutdown (ESD), fire & gas protection, burner management and turbine safety control, widely used in oil & gas, chemical, power and other SIL3 safety-critical industrial sites. Comprehensive onboard self-diagnosis, watchdog and fault snapshot functions help maintenance personnel quickly locate faults and reduce plant downtime. Replacement requires strictly matched firmware and system configuration.
Triconex 3006 MP3006 EMP II Main Processor 2MB SRAM
| Parameter | Specification |
|---|---|
| Product Type | Main Processor Module |
| Compatible System | Triconex Tricon EMP II Safety Instrumented System (SIS) |
| Core Function | Triple modular redundant main processing unit, safety logic execution, interlock calculation, process closed-loop control, backplane & TriBus communication scheduling |
| Signal Type | Backplane TriBus interface, isolated serial diagnostic ports, I/O bus signal, fault status signal |
| Galvanic Isolation | Reinforced isolation for communication ports, EMC and surge protection for industrial cabinet environment |
| Power Supply | 24 V DC, 18–32 V DC wide input |
| Power Consumption | Max 16 W |
| Diagnosis | Power-on self-test, watchdog supervision, channel voting fault detection, communication error logging, fault snapshot & event storage |
| Indicator | Onboard LED for power, run, link, alarm and fault |
| Communication | TriBus high-speed backplane bus, isolated RS232 diagnostic port, RS485 I/O communication bus |
| Hot Swap | Hot swappable in matched Tricon rack |
| Operating Temperature | -20 ℃ ~ +70 ℃ |
| Storage Temperature | -40 ℃ ~ +85 ℃ |
| Humidity | 5% – 95%, non-condensing |
| Protection Class | IP20 when installed inside cabinet |
| Certifications | SIL3, IEC 61508, CE, UL certified |
| Mounting | Plug-in eurocard board for Triconex EMP II rack |
| Remarks | 3006, Model: MP3006; 2MB SRAM; TMR triple redundant architecture; firmware version must match the whole SIS system; critical master spare of the safety control platform |

- TRICONEX Emp