Description
WOODWARD 9907-149 ProTech 203 Electronic overspeed protection device
Woodward 9907‑149 is the ProTech 203 triple redundant electronic overspeed trip system designed for critical rotating prime movers. It accepts three separate magnetic pickup signals, calculates speed independently on each channel and executes trip via two‑out‑of‑three voting logic. The unit adopts de‑energize‑to‑trip relay architecture to satisfy machinery safety standards. It features on‑board self‑test function allowing online verification without shutting down the machine, remote reset capability, and non‑volatile storage for peak speed and trip event history. The front LCD and keypad enable local configuration and readout, while Modbus serial communication transmits real‑time speed and diagnostic data to DCS or host monitoring system. This unit is a mainstream safety spare for turbine overspeed protection; replacement requires correct power variant, programmed trip setpoints and compatible MPU sensors.
WOODWARD 9907-149 ProTech 203 Electronic overspeed protection device
| Parameter | Specification |
|---|---|
| Product Type | Triple Channel Digital Overspeed Protection System, ProTech 203 |
| Compatible System | Woodward ProTech 203 Turbine Overspeed Trip System |
| Core Function | Independent triple redundant speed measurement from three magnetic pickup (MPU) sensors; implements two-out-of-three voting logic for overspeed trip; supports built‑in online self‑test, remote reset, peak speed capture, MPU fault monitoring and de‑energize‑to‑trip relay output compliant with API 670 |
| Signal Type | 3 × MPU magnetic pickup input, input impedance 2 kΩ; alarm and trip relay contacts; RS232 / RS422 Modbus communication; local keypad and LCD operator interface |
| Galvanic Isolation | Galvanic isolation between MPU inputs, relay circuits and internal logic; meets industrial EMC and surge requirements |
| Power Supply | 120 Vac/dc for this ordering code 9907‑149; alternative power variants available |
| Power Consumption | Max 75 W |
| Diagnosis | Power‑on self‑test, continuous MPU cable break / low signal detection, internal watchdog, built‑in frequency simulator for on‑line function test, trip cause storage, peak speed logging |
| Indicator | Front panel LCD display, function keypad, LED status for run, fault, alarm and trip |
| Communication | RS232 / RS422 Modbus RTU for configuration, speed trending and event upload |
| Hot Swap | Supports hot module replacement |
| Operating Temperature | -25 ℃ ~ +60 ℃; display rated -15 ℃ ~ +60 ℃ |
| Storage Temperature | -40 ℃ ~ +85 ℃ |
| Humidity | Compliant with MIL‑STD‑810D Method 507.2, non‑condensing |
| Protection Class | NEMA 4 / 4X, IP65 enclosure with stainless hubs |
| Certifications | UL / CSA certified, Class I Div 2 approved, API 670 compliant |
| Mounting | Panel mount enclosure |
| Application | Steam turbine, gas turbine, reciprocating engine, compressor; critical prime mover overspeed protection for power, oil & gas and petrochemical plants |
| Remarks | 9907‑149, ProTech 203; adjustable trip range 250–25000 RPM; max response time 40 ms; speed sampling interval 5 ms; configurable gear teeth 20–120; widely used as primary electronic overspeed protection; available as aftermarket spare; firmware and trip setpoints must match turbine safety design |