Description
ALSTOM | N897163510Q | N897163050Q MODEM | N897163100U
Alstom N897163510Q, N897163050Q and N897163100U form a matched three‑board traction control assembly for TRENO propulsion and TCMS. N897163510Q is the main CPU board that executes traction control algorithms and handles vehicle communication. N897163050Q is dedicated to resolver signal conditioning to acquire traction motor position and speed. N897163100U is the on‑board power interface board which provides stable regulated power rails and monitors supply quality. The assembly is built to withstand heavy vibration, shock and harsh electromagnetic environment of railway vehicles. It is stocked as a calibrated matched replacement set for the maintenance of Alstom metro and locomotive traction converters.
ALSTOM | N897163510Q | N897163050Q MODEM | N897163100U
| Parameter | Specification |
|---|---|
| Product Type | Matched Traction Control PCB Assembly |
| Compatible System | Alstom TRENO rolling stock traction converter and TCMS system |
| Core Function | Closed‑loop traction motor control, resolver signal acquisition, analog and digital I/O conditioning, on‑board communication, fault recording and continuous self‑diagnosis; three PCBs work as one calibrated matched set |
| Signal Type | Resolver feedback channels, analog measurement inputs, isolated binary I/O, CAN bus, RS485, 10/100 Ethernet, high‑speed internal inter‑board bus |
| Galvanic Isolation | Reinforced isolation for resolver, field I/O and communication interfaces, compliant with EN 50121 railway EMC standard |
| Power Supply | Nominal 110 V DC railway auxiliary input, generates internal regulated 24 V and 5 V logic supplies |
| Power Consumption | Max 26 W for the complete three‑board set |
| Diagnosis | Power‑on self‑test, resolver signal supervision, overvoltage / undervoltage detection, overtemperature monitoring, watchdog supervision, communication timeout, short‑circuit and wire break detection, persistent fault event logging |
| Indicator | RUN, FAULT, LINK and channel status LEDs located on the main board N897163510Q |
| Communication | CANopen, Modbus RTU, Ethernet, dedicated internal board‑to‑board bus |
| Hot Swap | Non hot‑swappable; main traction high voltage and auxiliary DC supply must be fully isolated before replacement |
| Operating Temperature | -40 ℃ ~ +70 ℃ |
| Storage Temperature | -40 ℃ ~ +85 ℃ |
| Humidity | 5% ~ 95% non‑condensing |
| Protection Class | IP00, installed inside sealed traction converter cabinet |
| Certifications | EN 50155, EN 50121, IEC 61508 SIL 2, CE |
| Mounting | Slide‑in rack PCB assembly for traction control cabinet |
| Application | Alstom metro and mainline rolling stock, traction propulsion and train control monitoring system |
| Remarks | Matched set: N897163510Q (main CPU control board), N897163050Q (resolver & signal conditioning sub board), N897163100U (power interface daughter board); legacy railway spare, supplied and tested only as matched set |