ALSTOM | NRD108034 | 8RDB44674G01 | SA44674.C | Industrial control board
Alstom NRD108034 (assembly code 8RDB44674G01, drawing reference SA44674.C) is a sixteen‑channel digital input Eurocard designed for ALSPA P320 and TGP turbine control racks. It captures contact status from field switches, limit contacts and relay outputs, with built‑in debounce filtering to suppress transient noise. Validated binary states and diagnostic information are sent to the rack controller via the dedicated backplane bus. Onboard diagnostics monitor input integrity and record events with timestamps for post‑fault analysis. This obsolete module is a critical stocking spare for legacy turbine and distributed control systems in power and process plants.
ALSTOM | NRD108034 | 8RDB44674G01 | SA44674.C | Industrial control board
| Parameter | Specification |
|---|---|
| Product Type | 16‑Channel Isolated Digital Input Module |
| Compatible System | Alstom ALSPA P320, TGP turbine control and legacy power plant DCS rack |
| Core Function | Acquire dry / wet contact status, signal filtering, debounce processing, time‑stamped event capture, transmit validated digital status to rack main controller |
| Signal Type | 16 isolated digital input channels, nominal 24 VDC; supports dry contact and 24 V wet contact sensing; proprietary backplane bus interface |
| Galvanic Isolation | Galvanic isolation between field circuit and logic backplane, dielectric strength ≥ 1500 V AC |
| Power Supply | 24 V DC supplied by rack backplane |
| Power Consumption | Max 6.8 W |
| Diagnosis | Power‑on self‑test, input loop supervision, wire break detection, watchdog monitoring, overtemperature check, timestamped fault and event log |
| Indicator | RUN, FAULT and individual channel status LED indicators on front panel |
| Communication | Alstom proprietary rack backplane bus |
| Hot Swap | Non hot‑swappable; rack auxiliary power and field circuits shall be isolated before replacement |
| Operating Temperature | -25 ℃ ~ +70 ℃ |
| Storage Temperature | -40 ℃ ~ +85 ℃ |
| Humidity | 5% ~ 95% non‑condensing |
| Protection Class | IP00, installed inside sealed control cabinet |
| Certifications | CE, UL, IEC 61131‑2, IEC 61000‑6‑2 / IEC 61000‑6‑4 EMC compliant |
| Mounting | 3U Eurocard slide‑in rack PCB |
| Application | Thermal power turbine protection, boiler interlock, ESD, petrochemical process status acquisition |
| Remarks | NRD108034: base part number; 8RDB44674G01: full assembly revision code; SA44674.C: schematic drawing reference; discontinued legacy spare, fully function tested before shipment |

- NRD108034 |8RDB44674G01| SA44674.C