Description
EPRO MMS6120 Monitoring controller MMS 6120
EPRO MMS6120 is a dual‑channel bearing vibration monitor in the Emerson MMS6000 TSI machinery protection family. It accepts signals from electrodynamic velocity transducers or piezoelectric accelerometers to continuously measure bearing vibration velocity and displacement. A keyphase input enables rotational order analysis and spectrum capture. Each channel provides isolated 4–20 mA analog output for DCS trending, buffered dynamic signal for oscilloscope diagnosis and configurable pre‑alarm and danger relay outputs. The module records vibration snapshots during machine run‑up and run‑down for post‑trip review. Built‑in diagnostics detect sensor failures and abnormal signals, and all configuration parameters are password locked. Serial interfaces support local commissioning and Modbus RTU data uploading. This module is widely deployed for bearing vibration protection of critical rotating machinery; original manufacturing has been discontinued, and replacement requires identical model and compatible project configuration.
EPRO MMS6120 Monitoring controller MMS 6120
| Parameter | Specification |
|---|---|
| Product Type | Dual‑Channel Bearing Vibration Monitor Module |
| Compatible System | EPRO MMS 6000 Machinery Monitoring System (Emerson / Baker Hughes) |
| Core Function | Two independent measuring channels for bearing vibration; measures vibration velocity RMS, displacement peak‑peak and zero‑peak values; supports keyphase input for order analysis, adjustable pre‑alarm and danger relays, run‑up / run‑down recording, sensor fault detection and FFT spectrum function |
| Signal Type | Input for electrodynamic velocity sensor PR9266 / PR9268 or piezoelectric accelerometer, keyphase pulse input, isolated 4–20 mA analog output per channel, buffered dynamic signal output, SPDT alarm relay contacts, RS232 local configuration, RS485 Modbus RTU |
| Galvanic Isolation | Galvanic separation for sensor circuits, analog outputs, relay contacts and backplane; compliant with EN 50081‑1, EN 50082‑2 and API 670 |
| Power Supply | 18–31.2 V DC, redundant diode‑isolated power inputs |
| Power Consumption | Max 6 W |
| Diagnosis | Power‑on self‑test, sensor break / short detection, signal plausibility check, watchdog supervision, alarm inhibit, password protected parameter setup |
| Indicator | RUN, FAULT, PRE‑ALARM, DANGER and per‑channel status LED indicators on front plate |
| Communication | RS232 for commissioning, RS485 Modbus RTU for host and DCS trending |
| Hot Swap | Hot‑swappable within MMS6000 rack |
| Operating Temperature | -20 ℃ ~ +60 ℃ |
| Storage Temperature | -40 ℃ ~ +85 ℃ |
| Humidity | 5% ~ 95%, non‑condensing |
| Protection Class | Module IP00, front panel IP21 |
| Certifications | CE, IEC 61000, API 670 |
| Mounting | Eurocard DIN 41494, 6 TE / 3 HE plug‑in module for MMS6000 rack |
| Application | Steam turbine, gas turbine, centrifugal compressor, fan and gearbox; bearing vibration protection for power, petrochemical and metallurgical plants |
| Remarks | MMS6120, part number 9100‑00002; frequency range 10–1000 Hz for velocity measurement; stores run‑up / run‑down vibration snapshots; original production discontinued, supplied as aftermarket spare parts; firmware and configuration must match the existing MMS6000 rack |